Use the buttons below to pay with your Credit Card:
|
|
40 Watt Power Supply technical info below:
| Specifications: |
Input Voltage Range: 90 ˜ 264Vac
Input Frequency Range: 47 ˜ 63Hz |
Operation Temp: ˜ 30 +60¡ãC
Temp.De-rating: 1% per ¡ãC at 60 ~ 70¡ãC% |
| Input Current: Max. 115V/0.5A, 230V/0.25A |
Storage Temp.: ~ 40¡ãC ˜ + 85 ¡ãC |
Input Inrush Current: <5A/115V, 10A/230V
Power Factor: >0.9 at Full Load, 115Vac |
Humidity (Non ¨C Condensing): 5% ˜ 90%
Vibration Frequency: 5 ˜ 50 Hz, Shock: MIL-STD-810E |
| Leakage Current: 300uA Typical |
MTBF ( @ 25 ¡ãC): >100,000 Hours. MIL-217F |
Efficiency: 84% Typical at full
Protection: OCP, OVP, SCP ¨C Auto |
UL(cUL)1310, UL(cUL)48 Class 2 Approved
Compliance ¨C 47CFR Part 2 and CISPR B,CE Recovery |
| Model |
Working Voltage |
DC Output Current (A) |
MAX. Watts. |
OCP (A) |
OVP Regulation
(V) Load Line |
| LP 1040-12 |
12V |
0-3.33 |
40 |
5.2 |
15-18 3% 1% |
|
Click here to shop and pay with your paypal account!
Features:
40 Watts Max, 12VDC Constant Voltage Output. Fits in standard electrical 4x4 junction boxes. Suitable for dry or damp locations, IP66, NEMA4. Convection cooled, plastic housing. UL (cUL)1310, UL (cUL)48 Class 2, FCC, CE Certified 3 Year Warranty.
|